The high performance flange mounted differential pressure transmitter models EJA210A and 220A can be used to measure levels of densities of solidifying or precipitating liquids. Both output a 4 to 20 mA DC signal corresponding to the measured differential pressure.
The EJA Series is available with BRAIN, HART, FOUNDATION™ fieldbus or PROFIBUS PA communication protocols.
Specifications
EJA210A / EJA220A |
||
M Capsule |
H Capsule |
|
Range |
-100 to 100 kPa |
-500 to 500 kPa |
Span |
1 to 100 kPa |
5 to 500 kPa |
Accuracy |
±0.2% |
±0.2% |
Degrees of protection |
IP67, NEMA 4X, and JIS C0920 immersion proof |
|
Certificates |
FM, CENELEC ATEX, CSA, IECEx |
|
Output |
4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication |
|
Supply voltage |
BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) |
|
Ambient temperature |
-40 to 85 deg C (-40 to 185 deg F) (general use type) |
|
Process temperature |
-40 to 120 deg C (-40 to 248 deg F) (general use type) |
|
Maximum working pressure |
Flange rating pressure |
|
Mounting |
Flange mounting |
|
Process flange size |
EJA210A: 3-inch (80mm), 2-inch (50mm) |
|
Diaphragm material |
SUS316L, Hastelloy C-276, Tantalum |
|
Process flange material |
S25C, SUS304, SUS316 |
|
Housing |
Cast aluminum alloy or SUS316 equivalent stainless steel (optional |
www.chinaguiding.com/